You can connect this counter to your PC. Good for R/D and product promotion. The specially designed software installed on your PC displays the ion count data shown in waveform, which you can save and print out.
The specially designed software, which comes with the counter, displays the ion count data shown in waveform and the maximum / minimum / average ion count. You can save and print out the data. Good for making a report!
It conforms to the JIS B 9929 Standard*1 *2.
It is affordable yet provides highly accurate ion measurement. Good for R/D & Product Promotion.
It is good for low-concentration ion measurement of e.g. 10–500 (pcs/cc).
It measures positive or negative ions.
It measures a wide range of ion counts from 0–2,000,000 (pcs/cc) with high accuracy.
It is easy to carry around as it weighs 995 g only.
*1 JIS B 9929: Standard for measuring methods of airborne ion density. What is JIS? *2 Product structure and ion-count conversion formula only — measurement method not applicable.
Outline specifications
Accuracy
High
Measurement range
0 – 2,000,000 (pcs/cc)
Detectable ion
Positive / Negative small air ions
Measurement method
Ebert Gerdien capacitor method conforming to the JIS standard
Runs on
AC adaptor 100–240VAC (50/60Hz)
Weight
approx. 995 g
PC connectable
Yes
Applications
Room, Tourmaline sheet, Natural ores / Ceramics, Ion generator, Ion dryer, etc. R/D & Product Promotion.
Reason(s) why I purchased from you: We had used this product before, and when we decided to purchase it again, we found Ion Trading through Google and placed our order with you. The shipping was very fast, and all of the accessories were included as described. We are very satisfied with both the product quality and your excellent service. Thank you!
I am happy because: 1. You offer a good price on your website. 2. The software helps to collect ion data easily. 3. You contacted me to see if I was happy with the product. Great customer support! Other comments: You need to revise the website as the following items were not included in the package. 1. Pre-shipment inspection sheet 2. RS-232C Cable (reverse) 3. USB serial conversion cable It would be great if you offered a demo unit and a short course to learn how to use the counter. [From Ion Trading] Thank you for your feedback. We apologize for not including the accessories. You will soon receive these items as we are about to ship them.
Thank you for selling the ION Counter.I checked how is working and it is a high quality product. I connected to the computer and everything works. I will use it for scientific research activity.
See all 3 Customer ReviewsRating: 4.3[Please note]
These are individual impressions and do not guarantee the efficacy or performance of the product; results vary from person to person. If you require medical treatment, please consult a physician. Reviews of other products in the same series are also included. Reviewers may receive a small gift (a silicone bracelet) for posting a review; reviews are not selected or filtered based on their content, and only expressions that violate applicable laws or regulations may be edited, with the reviewer's understanding. Customer Reviews originally written in Japanese are translated into English by Ion Trading.
Customer Reviews
PC Connectable Highly Accurate Air Ion Counter Tester COM-3200PRO II
Loading...
PC Connectable — You can Save / Open / Print out Ion Data
You can connect this ion counter to your PC. Using the specially designed software, which comes with the counter, you can save, open and print out files which contain the ion waveforms, ion count, temperature and humidity. It will help you to make a report.
Affordable yet Highly Accurate, Conforming to the JIS Standard
✔ Affordable yet highly accurate, conforming to the JIS standard
The COM-3200PRO II, which conforms to the JIS standard*1 *2, provides highly accurate ion measurement. It meets professional requirements.
Most high-end ion counters employ the Gerdien capacitor detector; however, very few of them are in this price range. Good for R/D & Product Promotion!
*1 JIS B 9929: Standard for measuring methods of airborne ion density. *2 Product structure and ion-count conversion formula only — measurement method not applicable.
✔ Highly reliable Japanese Gerdien capacitor detector
*3 The parallel flat plate type detector, used in many lower-priced ion counters, can give unstable measurement as it disrupts the flow of the intake air in the detector. *4 Laminar flow: nonturbulent motion of a fluid in which parallel layers have different velocities relative to each other. (Collins English Dictionary)
Comparison of the detectors
Generally there are two kinds of detectors. This high-end ion counter uses a Gerdien capacitor detector (double coaxial cylinder type); lower-priced models usually use a parallel flat plate detector.
Provides highly accurate measurement as the air flow is relatively stable in the detector. Good for low-concentration measurement (e.g. 10–500 pcs/cc) as well as high concentration. All JIS-compliant ion counters use this type.
B · lower-priced models
Parallel flat plate ion detector
Does not provide highly accurate measurement as the air flow is not stable in the detector. Not good, particularly for low-concentration measurement.
✔ Minimizes the impact of static electricity
The COM-3200PRO II is designed to minimize the impact of static electricity, which can cause inaccurate measurement. It ensures a highly accurate measurement.
Data Collection Software
This software installed on your PC displays the ion count data. You can save and print out the data. It will help you to make a report.
You can view and print out:
Ion waveforms
Minimum / Maximum / Current / Average ion count
Date / Temperature / Humidity
You can open saved files and view them at any time. You can connect this counter to your PC via RS-232C or USB. This software is compatible with Windows 98/ME/2000/XP/Vista/7/8/10/11.
How to Use
1
Open the zero adjustment cover
Open the zero adjustment cover. The counter cannot suck in the air when the cover is closed.
2
Turn on
Turn on the power switch.
3
Start measurement
Place a measurement sample close to the air suction opening. The ion count is shown on the LCD display of the counter and on the PC screen. The image below shows 1,810 (pcs/cc) of negative ions generated by radium ceramic balls.
Measurement range: You can manually change the measurement range — X1 = 0–20,000 / X10 = 0–200,000 / X100 = 0–2,000,000 (pcs/cc).
Zero adjustment: We suggest you should perform zero adjustment for an accurate measurement. It takes only 1 minute. Start zero adjustment after doing several measurements and the reading stabilizes.
LCD display: The LCD shows ion count / temperature / humidity.
Positive ↔ Negative: You can manually switch between positive and negative ion measurement.
Demonstration Videos & Photos of Actual Measurements
Demonstration videos
Actual measurement & PC display screen (1)1:44 / No sound, with subtitles
Actual measurement & PC display screen (2)2:10 / No sound, with subtitles
Photos of actual measurements
Personal ion generatorRadium sheetRadium ceramic ballsTourmaline sheetIon supporterHigh-density ion generator
* The readings shown on the LCD display are not exact measurement results.
Package Contents
Air ion counter
Radium sheet for test operation
Specially designed 100–240VAC compatible AC adaptor
Instruction manual
Specially designed leather case
Cover of the air suction opening
Warranty card
Specially designed software
RS-232C Cable (reverse)
USB serial conversion cable
Part Names & View of the COM-3200PRO II
Part names
Front panelRight side panelLeft side panel
View of the COM-3200PRO II
Q & A
Ion counter
1. Can I measure natural ores which emit radiation?
Yes, you can if the natural ores emit a certain amount of radiation. However, we suggest you should use the ion counter for natural ores if the radiation is a very small amount.
2. Do I need to perform zero adjustment before starting measurement?
We suggest you should conduct trial measurements 10 minutes after you turn it on and then perform zero adjustment after the reading stabilizes. This will ensure precise zero adjustment.
3. Is it difficult to perform zero adjustment? How long does it take?
It is easy and it takes a minute or two under stable ambient conditions.
4. What is the ideal distance between the detector and the sample?
There is no ideal distance. However, the ion count detected by the counter can be lower than it actually is when the sample is too far away from the counter. 10mm +/- will be fine. Please be sure that the sample never makes contact with the detector.
5. How long is the time interval between data collection?
Ion count data is collected every second.
6. Can I save data in the counter?
No, you cannot. The software, which comes with this product, enables you to save data on your PC.
7. Can I measure ion densities in water?
No, you can't. This ion counter is for air ions.
8. What is the lowest ion density this counter can measure?
It is 10 (pcs/cc).
9. Can I use it outdoors?
Yes, you can. (FYI:) It takes 4 hours +/- to charge the rechargeable built-in battery and then the counter works for 8 hours +/-.
10. Does the software, which comes with the product, enable me to control the counter remotely?
You cannot control the counter remotely. The software is designed to display ion data on your PC.
11. Do I need to adjust the detector?
No, you do not need to.
12. Do I need to connect the counter to the ground?
Normally, you do not need to. We suggest you should connect it to the ground when the air is dry and static electricity is generated.
13. Please tell me why the measurement tolerance is not found in the specifications.
It is not included because there is no official standard to measure air ions and the tolerance. Measurement tolerances can be found in specs of products supplied by other companies but they can be theoretically calculated values.
FYI: The theoretically calculated measurement tolerance of the COM-3200PRO II is close to zero due to the precisely designed, manufactured and adjusted detector.
14. What are the main differences between this counter and other low-priced products?
The COM-3200PRO II has these advantages.
Despite the compact body, it provides stable measurement as it uses a detector ensuring large air flow.
The precisely designed, machined, finished and adjusted Japanese Gerdien capacitor provides highly accurate ion measurement.
The counter is designed to minimize the impact of static electricity which can cause inaccurate measurement.
15. Can I use this ion counter in my country? I think the voltage and AC plug are different from Japan.
You can use the COM-3200PRO II in most countries as it works with AC100-240V and comes with the AC plug adaptors for the countries.
Data collection software
1. What OS does this software support?
It is compatible with Windows 98/ME/2000/XP/Vista/7/8/10/11.
2. What interface does this counter have?
You can connect it to your PC via RS-232C or USB.
3. What do I have to do to print out?
You need to install the driver for your printer and connect the counter to the PC.
4. Can I connect to our LAN to share data?
Yes, you can, but you need to set up the LAN connection.
5. Is this software compatible with Mac OS?
No, it is not.
Maintenance work
1. Does the counter require calibration? If it does, how often does it need to be calibrated?
We cannot calibrate the COM-3200PRO II because there is no reference device for ion counters. We can inspect whether your COM-3200PRO II works properly according to our standards. Normally, it does not require inspection if it is used under normal conditions. However, the detector can accidentally suck in foreign particles, which could cause inaccurate measurement. Please contact us if your counter seems to be working improperly. We can inspect the detector.
2. Can I clean the detector by myself?
No, you cannot. Please contact us if it needs to be cleaned.
Others
1. Can I return the counter?
We accept returns within 8 days of delivery.
2. Do you offer a rental service?
No, we do not.
Specifications
Full specifications
P/N
COM-3200-PRO-II
Product name
PC Connectable Highly Accurate Air Ion Counter Tester COM-3200PRO II
Detectable ion
Positive / Negative small air ions
Measurement method
Ebert Gerdien capacitor method conforming to the JIS standard